Electrical Fittings For Safe Electrical System | Emerson US

05, Jun. 2025

 

Electrical Fittings For Safe Electrical System | Emerson US

If the air is filled with flammable vapors, dusts and other dangers, selecting the correct fitting is a must. Even in an ordinary location, the right fittings make the job easier while ensuring a safe, durable electrical system. This is not the place to cut corners. Whether you are wiring an office building or an offshore oil platform, we have all the top quality products you need.

Read more

When specifying electrical products for harsh environments choosing the right materials to ensure adequate corrosion resistance is crucial. Most industrial electrical products worldwide use ferrous metals which take advantage of iron’s strength, versatility, workability and relative affordability. As ferrous products are most susceptible to corrosion, it is important to understand the finishing processes a manufacturer applies to protect their electrical products from the surrounding corrosive environment.

Solved: Using ELECTRICAL Connectors - Autodesk Community

I am trying to use power connectors, in this case the balanced power connector, to circuit equipment on a project.  I need help understanding how to use them.  When I place one and click on it to reveal its properties it reveals that everything under "Electrical - Loads" is grayed out.  It reveals under the "General" Heading "Panel Name".  A couple of questions:

1. Is "Panel Name" the name to be given to the connector?

2. Do I "Edit Type" and duplicate to make unique equipment connections in each case?  Seems like equipment name, load, load classification, etc., would be instance parameters to be used as I need it.

Thanks.

If "Panel Name" is an available parameter, the load values are gray because they'll be defined by the loads assigned to the equipment/devices downstream of that panel.  You can't just assign a load value to a panel, you have to create a system for which the panel is the source.

If the family you're using isn't intended to be a branch/distribution panelboard, you need to edit the family and change the category.

So it sound like this is not the device I want to use.  I simply want to connect a variety of equipment (Exhaust Fans, Air handling units, pumps, etc,) all either three phase or single phase 480 volt or 208 volt.  None of this equipment has electrical properties or at least most of them and nor am I at the point where I can take advantage if they do have electrical connectors.  Could be anything from an oven to a sterilizer.  For now I just want to set up a load connection and define the  parameters (volts, phase, KVA, description etc.,) that will tie back to a panelboard.  How do I do that?

So, the connectors are defined as Panels?  So you have to tie a load to a connector and then tie the connector to a panel?  I guess I need to get more information on how connectors work.  In the mean time how do I connect loads to my panelboards as described above?

Thanks.

For now I just want to set up a load connection and define the  parameters (volts, phase, KVA, description etc.,) that will tie back to a panelboard.  How do I do that?

Whoa.  OK, here's what you need - edit each of those families.  Make sure they have an electrical connector element in them (this is the model component that carries the load data from the equipment to the distribution source/panel).  Each connector will have a set of properties, volt/# of poles, apparent load, etc.  Map each of these properties of the connector element to a corresponding parameter in the family - I recommend using type parameters for most larger pieces of equipment and instance parameters for receptacles and the like.  Now when you load the families back into the project you can define the electrical characteristics of the equipment in the project environment, either through the Properties palette (instance parameters) or Edit Type (type parameters).

To create systems (circuits), select all of the devices you want to be ganged on a common circuit, choose the Power button from the ribbon, and presto, they're a circuit.

To connect these circuits back to a panel, select the panel and assign a distribution system to it (208/120 or 480/277 if you're in the US).  Once you've done that, go back to the devices/equipment, select any one of them, choose Edit Circuit, then choose the appropriate panel.

Goto Electric Powertek to know more.

When you say "edit each one of those families" I don't know quite what you mean.  I think I am having trouble explaining myself.

The equipment that I am trying to connect is mostly mechanical equipment.  However I have some equipment which doesn't have electrical connectors at all.  For instance we have a sterilizer that I have to connect.  No electrical properties or connector.  Just a box with dimensions from the Architectural model.  The electrical requirements are 208 volt, three phase, 30 KW.  I need to connect it to a panelboard so I have to have some generic power connection point that I can input data and connect it to a panelboard.

We are doing the Architectural, Mechanical, Electrical and plumbing for the project.  Architectural, Plumbing, Mechanical and Electrical all of separate models.  Some of the mechanical equipment has electrical data listed in its properties.  I don't know if it has an electrical connector but even if it does at this point I wouldn't know  how to use it or edit for my use.  So for those two I want a connection I can use to represent this equipment and feed it from a panelboard.  Thus I was tring to use the "Electrical Equipment - Balanced Power Connector" for the job.

Question: Should I use the 1, 2 or 3-pole junction box instead?

I want to Edit Type, Duplicate and create independent power connection for all this equipment if that can be done.

Thanks.

When you say "edit each one of those families" I don't know quite what you mean.

I mean that to create the electrical connectors you need to open the families independently - you can't add electrical connectors in the project environment.  

Revit has two working modes - project and family editor.  Families are loaded into a project and within that project parameter values can be edited.  To add/remove connectors, add/remove parameters, or change the geometry you have to edit the family directly.  You can either open the family (*.rfa) file directly from the Revit home screen, or select an object in a model and click "Edit Family" in the ribbon.

However, since all of the equipment you need to circuit appears to be in a separate linked model, I'd recommend simply using a j-box or motor family to create your circuits rather than screwing around trying to edit the families in someone else's model.

I think I understand what they are used for but perhaps you can confirm my understanding.  A receptacle and other electrical families require  a connector in order to connect them to your power system.  Light fixtures and receptacles for instance contain electrical connectors so that you can connect  them to the power distribution system.  I just don't know what to do with a generic electrical connector.  Do you modify them to include annotation and contain electrical characteristics to be used as a family in the project?  I could create an electrical pump or some other item for example to include in the project.

When I say generic electrical connectors in my case I am strictly talking about power.  I realize that there are connectors for other systems but I really haven't got into those just yet. Revit comes with families of Electrical Equipment Connectors.  Balanced Power Connector and Unbalanced Power Connector.  I was initially trying to use those to create an equipment connection for all of the equipment I have to connect to my panelboards in the project.  I was trying to customize these connections to contain the data for each piece of equipment (pump motors, air handling units, etc.): voltage, phase, KVA.  I would then connect them to panelboard which created a circuit.  But these don't seem to work that way.  Someone pointed me to the use of junction boxes which seems to be what I really needed to use.  I still don't know what these connectors do or how to use them at this point but I think my problem is solved by using the junction boxes.

Not possible.  Those connector properties are hard-coded into Revit and can't be altered.  The closest you can do is create shared parameters for V, A, VA, and Phase, then make the VA parameter equal to V * A * sqrtPhase.  But, because Revit hates us, you cannot use parameters that will link with the phase property in the connector in formulas, so you have to create yet another parameter to fill in the equation.

Or just throw up your hands, continue doing that calc manually, and drink.

Want more information on electric power fittings factory? Feel free to contact us.