An autotransformer is a type of electrical transformer that utilizes a single coil to adjust voltage, meaning there is no isolation between the primary and secondary circuits.
Please visit our website for more information on this topic.
Similar to a typical isolation transformer, autotransformers transfer electrical energy from one circuit to another while changing the voltage. But unlike isolation transformers where the windings are completely separate, the primary and secondary of an autotransformer are electrically connected.
Autotransformers are often employed as a cost-effective substitute for 3-phase general purpose distribution transformers for adjusting supply voltage for particular load requirements, provided that isolation from the supply line is not necessary.
Below are some examples of autotransformer applications, and installation considerations.
Autotransformers are ideal for voltage adjustment for commercial and industrial machines. They provide an efficient, low-cost way of serving the proper voltage to motors and compressors, lathes, CNC machines and other industrial equipment requiring a step up or down from a building’s service voltage. Their smaller profile is often half the size of a standard two winding transformer, which makes for a discreet installation. If only a minor voltage conversion is needed, a buck-boost transformer may be an effective option.
For applications deriving branch circuits from autotransformers, a connection to a grounded conductor from the system supplying power to the autotransformer must be made at the load side terminal of the transformer. This means there will be four wires connected at the primary and secondary of the autotransformer–three hot wires (ungrounded conductors) and a neutral (grounded conductor). The electrical code allows for two exceptions to this rule as follows:
“Exception No. 1: An autotransformer shall be permitted without the connection to a grounded conductor where transforming from a nominal 208 volts to a nominal 240-volt supply or similarly from 240 volts to 208 volts.”
“Exception No. 2: In industrial occupancies, where conditions of maintenance and supervision ensure that only qualified persons service the installation, autotransformers shall be permitted to supply nominal 600-volt loads from nominal 480-volt systems, and 480-volt loads from nominal 600-volt systems, without the connection to a similargrounded conductor.”
When going from 240V to 208V and vice versa, the NEC allows autotransformers to derive a branch circuit with a three wire connection on the primary and secondary sides–meaning you don’t need to supply a fourth wire (grounded conductor) from the system supplying power to the autotransformer.
This same rule can be applied in industrial occupancies with voltage transformations going from 480 to 600 and vice versa with the stipulation that there is proper maintenance and supervision present in the facility to ensure only qualified persons can service the transformer installation.
“We have used Maddox autotransformers on several ground-mount solar installations. It is quite common for commercial-scale PV inverters to produce 600 volts, but the auxiliary equipment requires lower voltages such as 380, 400, or 480 volts. Autotransformers make it very easy to achieve that voltage conversion.”
Because autotransformers do not isolate the incoming and outgoing line and load circuits they are connected to, it is generally not recommended that the neutral point of the windings be bonded to ground. Grounding the neutral point may create objectionable ground current paths with an already present neutral ground bond in the system.
This should not be confused with the equipment grounding conductor (or bare copper wire) that is connected to the metal enclosure of the transformer (commonly referred to as a “case ground”). The case of the transformer should be grounded per standard electrical code regulations.
The HV and LV neutral connections on Maddox’s autotransformers are typically brought out as a single common H0/X0 terminal. When an autotransformer supplies power to a load that requires a neutral (fourth wire), a grounded conductor (neutral) from both the line and load sides of the circuit must be landed at the H0/X0 terminal. In other words, you cannot supply a load from the transformer with four wires if you only bring three into it from the supply end–you have to have four wires in and four wires out.
A three wire connection on the incoming and outgoing terminals is commonly used as well. In such cases, the neutral ground bond at the source supplying power to the autotransformer is referenced from its point of origin all the way through to the load being served by the autotransformer.
All of these restrictions and rules can be a lot to take in if you’ve never dealt with autotransformers before, so we’ve boiled the basic rules of thumb down with quick reference table as follows:
For more information, please visit Tianya.
“Alpha builds custom hydraulic elevator controls, and we occasionally need to supply a transformer with the package to change the building voltage to work with our controls. Autotransformers are great because they’re less expensive than regular isolation transformers while getting the same exact job done. We pass the savings on to the customer.”
If you are unsure if an autotransformer is compatible with a particular piece of equipment, we recommend contacting the equipment manufacturer. However, as a general rule, this issue goes beyond the scope of an equipment manufacturers’ specifications since it is largely dependent on the existing electrical system configuration, where the equipment is installed, and local code requirements which we covered in the first part of this article.
One hard and fast rule around autotransformer use, is that if the machine requires a neutral, and your system does not have one, an isolation transformer is required to create that neutral. Autotransformers do not create their own neutrals.
Beyond that, machine manufacturers are often more focused on the what (volts and amps) rather than the how (isolated or not) when it comes to power supply. But there are two types of equipment that we have noticed tend to prefer isolation transformers:
Learn more about transformer sizing and design requirements—inverters, harmonics, DC bias, overload, bi-directionality, and more.
There are four main ways in which autotransformers differ from isolation transformers: construction, voltage transformation, voltage regulation and impedance, and size and efficiency.
Transformer windings are made out of either aluminum or copper; there’s no substantial advantage to either winding material. Here at Maddox, we use copper windings for all of our autotransformers.
If you need help deciding if an autotransformer is right for you or need a custom autotransformer built, please fill out the form below.
You can also purchase autotransformers directly from our online store.
A transformer is an electrical device that transfers electrical energy from an alternating current circuit to one or more other circuits, also used primarily to increase or decrease voltage. A transformer is made of two electrically isolated coils that work on the Faraday principle of mutual induction. During this process, an emf is induced in the secondary coil of the transformer by a change in the magnetic flux flowing in the primary coil winding.
To avoid wastage of energy in a transformer, a magnetic field is created between the transformer core primary and secondary coil, which directs the path of current flowing. The electrons start moving when the magnetic field is created within the secondary coil, resulting in the creation of an electric current through electromotive force.
Some of the advantages of AC transformers are as follows:
The basic structure of conventional transformers has remained the same over the past decades, but advances in material technology have resulted in higher saturation densities and lower hysteresis losses in transformers, resulting in an efficiency of about 97 per cent for even very efficient transformers.
Power transformers provide highly efficient and long-distance power transmission, which helps to step up the voltage to a higher level on the output. The distribution system is used by distribution transformers to step down high voltage.
AC transformers have a few flaws. Some of the disadvantages of AC transformers are discussed below:
Transformers are used for a wide range of applications. A transformer, for example, is frequently used to reduce the voltage of conventional power circuits in order to operate low-voltage devices and to raise the voltage from electric generators in order to transmit power over long distances. Transformers play a significant role in our daily lives since they adjust the alternating current and deliver a consistent amount of electricity to the device. This ensures smooth operation and long life not only of a device but also of the transformer.
Are you interested in learning more about Power Transformer Supplier? Contact us today to secure an expert consultation!