What is the Difference between High Voltage and Hipot?

08, Jul. 2024

 

What is the Difference between High Voltage and Hipot?

When Cirris employees talk about high voltage testing with customers, we worry that some users get confused as to what exactly we mean. Do we mean hipot? A dielectric withstand test? Or something else?

If you are looking for more details, kindly visit our website.


 

High voltage testing summary

Generally, testing a cable takes place in two parts. First, a tester performs a low voltage test looking for basic errors such as opens, shorts, and incorrect wiring.

The second part of testing uses high voltage. This part of testing is not always expected, but will help find potential errors that could affect the cable later on. Many people know this part of testing as high voltage or hipot testing.

This article wont cover details of how high voltage testing works or exactly what problems this type of testing uncovers. For more information on high voltage or hipot testing, see the article in the Cirris Learning Center called, Testing Cables with High Voltage.

High voltage vs. hipot

Those who tests with high voltage can agree that the benefits are worth the extra time and money it takes. The disagreement comes when labels are placed on high voltage testing. Some people call it high voltage testing while some call it hipot testing. Each of these terms can mean different things to different people.

Some people think hipot means only a dielectric withstand test. Others see it as covering the whole spectrum of high voltage tests. Still others associate hipot and high voltage with other meanings.

With different people defining hipot in different ways, how can manufacturers be sure they are purchasing a high voltage or hipot tester that will meet their needs?

Cirriss Definitions

Cirris uses the terms high voltage and hipot interchangeably. For Cirris, both words refer to dielectric withstand tests and insulation resistance tests.

Cirris uses the terms high voltage and hipot interchangeably. For Cirris, both words refer to dielectric withstand tests and insulation resistance tests.

If you are ever speaking to a Cirris employee and worry that you each have a different definition of a word, dont hesitate to ask for clarification. We wouldnt want you to receive information that is incorrect because a word we used has a different definition than youre used to.


 

As for Cirris products, all Cirris high voltage testers perform both a dielectric withstand test and an insulation resistance test (along with all the basic low voltage tests). Order a free demo to discover the benefits of high voltage or hipot testing.

 

Image via: Wikipedia

 

Further reading:

What Do We Mean By Low Voltage Testing?

Hengfeng supply professional and honest service.

A Simple Way to Shorten High Voltage (Hipot) Test Time

Master Your CH2 Test System in 3 Simple Steps

 

Insulation Testing: Megohmmeter or Hipot Tester

There are two common methods for performing insulation tests on cables, wiring and electrical equipment. One uses a megohmmeter to measure insulation resistance. The other uses a hipot tester to check for insulation breakdown. Both apply a high voltage, either ac or dc, to the device under test (DUT) and measure the resulting current flow.

Megohmmeters
A modern megohmmeter (or megohm meter) applies a dc voltage to a DUT and measures the dc current (nanoamps or microamps). Applying Ohms Law, the corresponding resistance value is then shown on the meters analog or digital display. This instrument is often called a megger, which is a term trademarked by the Megger Group in .

In a typical megohmmeter, the user can select from several voltage levels. For cables or equipment with rated voltage up to 500V, the maximum dc test level is usually twice the rated voltage. Above a 500V rating, the maximum level is closer to the rated voltage (e.g. V for a V system). The equipment manufacturer may have more specific test recommendations.

Due to capacitance and dielectric effects in the DUT, it takes time for the reading to stabilize after the voltage is applied. Initially, the reading is dominated by capacitance charging. Absorption currents may be significant for 20 seconds or more. Usually, IR readings are made after 60 seconds to allow these effects to settle out.

Techniques
Two techniques can aid in insulation condition assessment. The first is to apply the voltage in increasing steps. Degraded insulation will show a declining IR value as the test voltage increases. For accurate results, dwell time at each step should be controlled. To make this an easy test, some megohmmeters include a function to automatically step up the voltage at programmed intervals.

Another assessment technique is to compare IR readings with previous test results. Since the megohmmeter uses a very low test current, it does not damage the insulation. Periodic IR testing will identify insulation degradation over time and the need for preventive maintenance. An accurate comparison requires measurements at the same voltage and dwell time. Moisture affects the IR readings, so care should be taken to perform the tests under similar temperature and humidity conditions.

Parameters
Two parameters derived from insulation resistance measurements are dielectric absorption ratio (DAR) and polarization index (PI). Advanced digital megohmmeters have dedicated functions to measure and display these parameters. DAR is the IR at 60 seconds divided by the IR at 30 seconds. A value less than 1 shows the resistance is decreasing with time, which indicates a failing DUT. The polarization index is used on motors and generators to assess the amount of impurities in the windings and their cleanliness. PI is the IR at 10 minutes divided by the IR at 1 minute. Some equipment standards specify minimum PI values. A ratio greater than 1.5 is generally adequate.

Handheld megohmmeters that source up to V are available from several manufacturers. Portable units can supply up 15kV. Multi-purpose instruments combine IR measurements with other test functions, such as a multimeter. This photo shows a typical handheld megohmmeter, portable megohmmeter, megohmmeter/DMM and hipot tester.


Hipot Tester
A hipot (short for high potential) test determines the ability of electrical insulation to withstand normally occurring over-voltage transients. The hipot tester applies high voltage to the insulation barrier of the DUT and verifies there is no breakdown. It is a simple pass/fail test performed as a type test on a representative sample unit or as a routine production test. Maximum allowed leakage is usually in the range of 0.1 to 5mA, or as specified in the test standard. The actual leakage value for each DUT may be recorded for quality assurance.

Many standards (such as IEC ) specify an ac test voltage that is twice the operating voltage plus V. Most allow the use of either ac or dc voltage. The test setup and procedures are identical for ac and dc, although the dc level should be equal to the ac voltage peak. The test time is normally 1 minute, but in some situations, such as high volume production testing, a shorter test time may be permitted at a higher voltage.

Typically, a hipot test is performed on the mains wiring of electrical equipment. One lead of the tester is connected to safety ground (earth ground). The other lead is connected to the line and neutral power leads. Often the hipot tester has a built-in ac receptacle to make these connections (as shown in the photo).

If the circuit under test has a power line filter, an ac hipot tester may indicate a failure due to current flow to earth thru the Y capacitors. The safety standard usually allows the user to disconnect these capacitors prior to testing or increase the upper current limit to compensate for the additional leakage. Alternatively, a dc test voltage can be used. Most hipot testers also include a low limit to ensure the test fails if the DUT is not connected or the test is interrupted. Unlike megohmmeters, which are usually battery-powered, almost all hipot testers require ac power.

In summary, insulation resistance is typically a field measurement to assess insulation quality. Hipot testing is usually a safety check performed in the factory to verify the product design and manufacturing process. This difference determines whether a megohmmeter or hipot tester is the appropriate insulation testing instrument.