When the lights go out you need reliable backup power. In the event of a fire or other disaster that cuts off electricity, people and property can be at risk. To mitigate that risk, your emergency lighting systems need to be ready at all times.

You will get efficient and thoughtful service from Godson Tech.

Functional emergency lighting, or egress lighting, is often required to meet state building codes, fire codes, insurance standards and OSHA requirements. The emergency lighting must provide illumination for all egress routes automatically and within seconds in the event of a power failure. There are also guidelines for how and how often to test the emergency lighting system. A monthly test with the lights on for at least 30 seconds and a longer yearly test is common.

How does emergency lighting work?

Emergency lighting and exit signage lights work in a similar fashion. The lights are connected to the electrical system of the building providing a constant charge to the batteries. When the power goes out, the batteries kick in providing light to illuminate the hallways and stairs that are part of the emergency exit paths.

When to replace the battery

Most emergency lighting units have self-test switches that provide an accurate battery reading. When either the monthly test or the annual test generate unsatisfactory results, the emergency light battery needs to be replaced.

In optimal environments emergency light batteries can last longer than the typical 4 years indicated by manufacturers, but the results of the testing should dictate replacement whether or not they reach the 4 year mark.

For more information, please visit Emergency Lighting Battery.

Types of replacement batteries

The emergency lighting battery must be replaced by a battery with the same voltage, dimensions and terminal type. For emergency lighting using sealed lead acid batteries, the voltage is usually 6v or 12v. Never replace a 12v battery with a 6v or a 6v with a 12v. This can cause your system to malfunction or cause damage to the lighting fixture.

The typical terminal type for a sealed lead acid backup battery is a faston tab. The fixture will be supplied with a connector that will slip over the tab on the battery to close the circuit. Some larger batteries have L terminals, which are also used on car batteries. These are rare unless the battery is large, and the fixture is rated for extended use during emergencies.

Although many exit signs now utilize LED bulbs and thus only require a small NiCad battery, there are older units and current dual units with emergency lights that are part of the exit sign that use sealed lead acid batteries. Similar testing protocols are in place for these units and proper maintenance and periodic battery replacement should be considered just as essential.

Where do I find alarm and emergency lighting replacement batteries?

BatteryClerk.com sells a wide variety of sealed lead acid batteries that are compatible with many brands of emergency lighting and exit signs. They offer 1-2 day delivery to most of the USA plus FREE shipping on orders over $99.

BatteryClerk offers high-quality, AJC-brand batteries that are built to last.  They give you the superior performance and the optimum power you need. When you use AJC replacement batteries, you have peace of mind that you will have the power, signage, and alerts needed in critical situations.

If you want to learn more, please visit our website Lithium Battery ICR mAh 7.4V.

Emergency light requirements - Mike Holt's Forum

So I'm in a boiler plant with several levels of flooring - all open catwalk, about 15 or so emergency battery back up fixtures moounted throughout. A couplke years back the plant was upgraded and noe the entire facility is backed up with a natgas gen set.

The work order says they'd like the failed Elites replaced. I looked through 700, 701, 702, and beyond a bit. Not sure I have my answer yet - my question is - are they still required to have those E lites in the plant when the entire plant is already backed up and the gen would pick up lighting?

Any thoughts guys??

Thank

Steve Building codes, not the electrical code, tell us when E-lights are needed. The NEC, article 700, tells us that if any load (such as E- lights) are required, by some code or other authority, to be on emergency power, then (THIS IS THE KEY POINT) those loads must be re-energized within 10 seconds of the loss of normal utility power. There are also a number of special requirements for the electrical configuration that would bring power from the generator to the emergency loads.

Can the newly installed gas generator meet these requirements? Yes, unless the generator and transfer switch is listed for use as an Emergency System, Article 700, you will need battery back up exit and egress lights...assuming that those are required by the building code. Although battery back-up "E" lights and Exits may seem as 'overkill', think about safety. I agree with Charlie & Don that you should maintain the units. You will not find anything in NEC, but think about being safe in the time between utility failure and gen startup.

BTW, what type of general lighting is in the area?? LED, Fluorescent, HID?? That can make a difference also. The requirement for generators start in the adopted building code. In most occupancies, natural gas generators are not UL so can't be used for article 700 or 701 loads.

In addition, the local jurisdiction likely has rules for when a natural gas gen can be used depending on the reliability of the gas source. Thanks guys! The plant has rod mounted 4' LED slim line fixtures. - But this is getting kicked up to Engineering at this point as the cost of the existing Lithonia E fixtures that are there now are about 750 bucks a piece. After a cost of bucks, this as to be sent out for bids, tus delaying me for a while.

Thanks for getting back to me tho fellas - appreciate that!

Steve