Pressure regulator

15, Jul. 2024

 

Pressure regulator

Control valve that maintains the pressure of a fluid or gas

ABYDA are exported all over the world and different industries with quality first. Our belief is to provide our customers with more and better high value-added products. Let's create a better future together.

Oxygen and MAPP gas cylinders with two-stage pressure regulators Schematic diagram of pressure reducing regulator (A) and back-pressure regulator (B). The upper diagrams show the normal state for the valves, which is normally open for pressure reducers and normally closed for back-pressure valves.
  • 1. Pressure setting screw
  • 2. Spring
  • 3. Actuator
  • 4. Inlet port (high pressure)
  • 5. Outlet port (low pressure)
  • 6. Valve body
  • 7. Valve crown and seat
Diagram symbols for pressure reduction and back pressure regulators. The conceptual difference is mainly in which side the feedback is taken from.

A pressure regulator is a valve that controls the pressure of a fluid to a desired value, using negative feedback from the controlled pressure. Regulators are used for gases and liquids, and can be an integral device with a pressure setting, a restrictor and a sensor all in the one body, or consist of a separate pressure sensor, controller and flow valve.

Two types are found: The pressure reduction regulator and the back-pressure regulator.

  • A pressure reducing regulator is a control valve that reduces the input pressure of a fluid to a desired value at its output. It is a normally-open valve and is installed upstream of pressure sensitive equipment.[1]

  • A back-pressure regulator, back-pressure valve, pressure sustaining valve or pressure sustaining regulator is a control valve that maintains the set pressure at its inlet side by opening to allow flow when the inlet pressure exceeds the set value. It differs from an over-pressure relief valve in that the over-pressure valve is only intended to open when the contained pressure is excessive, and it is not required to keep upstream pressure constant. They differ from pressure reducing regulators in that the pressure reducing regulator controls downstream pressure and is insensitive to upstream pressure.[2] It is a normally-closed valve which may be installed in parallel with sensitive equipment or after the sensitive equipment to provide an obstruction to flow and thereby maintain upstream pressure.[1]

Both types of regulator use feedback of the regulated pressure as input to the control mechanism, and are commonly actuated by a spring loaded diaphragm or piston reacting to changes in the feedback pressure to control the valve opening, and in both cases the valve should be opened only enough to maintain the set regulated pressure. The actual mechanism may be very similar in all respects except the placing of the feedback pressure tap.[2] As in other feedback control mechanisms, the level of damping is important to achieve a balance between fast response to a change in the measured pressure, and stability of output. Insufficient damping may lead to hunting oscillation of the controlled pressure, while excessive friction of moving parts may cause hysteresis.

Pressure reducing regulator

[

edit

]

Operation

[

edit

]

A pressure reducing regulator's primary function is to match the flow of gas through the regulator to the demand for fluid placed upon it, whilst maintaining a sufficiently constant output pressure. If the load flow decreases, then the regulator flow must decrease as well. If the load flow increases, then the regulator flow must increase in order to keep the controlled pressure from decreasing due to a shortage of fluid in the pressure system. It is desirable that the controlled pressure does not vary greatly from the set point for a wide range of flow rates, but it is also desirable that flow through the regulator is stable and the regulated pressure is not subject to excessive oscillation.[citation needed]

A pressure regulator includes a restricting element, a loading element, and a measuring element:

  • The restricting element is a valve that can provide a variable restriction to the flow, such as a globe valve, butterfly valve, poppet valve, etc.
  • The loading element is a part that can apply the needed force to the restricting element. This loading can be provided by a weight, a spring, a piston actuator, or the diaphragm actuator in combination with a spring.
  • The measuring element functions to determine when the inlet flow is equal to the outlet flow. The diaphragm itself is often used as a measuring element; it can serve as a combined element.[

    citation needed

    ]

In the pictured single-stage regulator, a force balance is used on the diaphragm to control a poppet valve in order to regulate pressure. With no inlet pressure, the spring above the diaphragm pushes it down on the poppet valve, holding it open. Once inlet pressure is introduced, the open poppet allows flow to the diaphragm and pressure in the upper chamber increases, until the diaphragm is pushed upward against the spring, causing the poppet to reduce flow, finally stopping further increase of pressure. By adjusting the top screw, the downward pressure on the diaphragm can be increased, requiring more pressure in the upper chamber to maintain equilibrium. In this way, the outlet pressure of the regulator is controlled.[citation needed]

F = ( P i ' P o ) s + P o S + f {\displaystyle F=(P_{i}-P_{o})s+P_{o}S+f}

F :  diaphragm spring force {\displaystyle F:{\text{ diaphragm spring force}}}


f :  poppet spring force {\displaystyle f:{\text{ poppet spring force}}}
P i :  inlet pressure {\displaystyle P_{i}:{\text{ inlet pressure}}}
P o :  outlet pressure {\displaystyle P_{o}:{\text{ outlet pressure}}}
s :  poppet area {\displaystyle s:{\text{ poppet area}}}

S :  diaphragm area {\displaystyle S:{\text{ diaphragm area}}}

Single stage regulator

[

edit

]

Single-stage pressure regulator

High pressure gas from the supply enters the regulator through the inlet port. The inlet pressure gauge will indicate this pressure. The gas then passes through the normally open pressure control valve orifice and the downstream pressure rises until the valve actuating diaphragm is deflected sufficiently to close the valve, preventing any more gas from entering the low pressure side until the pressure drops again. The outlet pressure gauge will indicate this pressure.[citation needed]

The outlet pressure on the diaphragm and the inlet pressure and poppet spring force on the upstream part of the valve hold the diaphragm/poppet assembly in the closed position against the force of the diaphragm loading spring. If the supply pressure falls, the closing force due to supply pressure is reduced, and downstream pressure will rise slightly to compensate. Thus, if the supply pressure falls, the outlet pressure will increase, provided the outlet pressure remains below the falling supply pressure. This is the cause of end-of-tank dump where the supply is provided by a pressurized gas tank.[citation needed] The operator can compensate for this effect by adjusting the spring load by turning the knob to restore outlet pressure to the desired level. With a single stage regulator, when the supply pressure gets low, the lower inlet pressure causes the outlet pressure to climb. If the diaphragm loading spring compression is not adjusted to compensate, the poppet can remain open and allow the tank to rapidly dump its remaining contents.[citation needed]

Double stage regulator

[

edit

]

Two-stage pressure regulator

Two stage regulators are two regulators in series in the same housing that operate to reduce the pressure progressively in two steps instead of one. The first stage, which is preset, reduces the pressure of the supply gas to an intermediate stage; gas at that pressure passes into the second stage. The gas emerges from the second stage at a pressure (working pressure) set by user by adjusting the pressure control knob at the diaphragm loading spring. Two stage regulators may have two safety valves, so that if there is any excess pressure between stages due to a leak at the first stage valve seat the rising pressure will not overload the structure and cause an explosion.[citation needed]

An unbalanced single stage regulator may need frequent adjustment. As the supply pressure falls, the outlet pressure may change, necessitating adjustment. In the two stage regulator, there is improved compensation for any drop in the supply pressure.[citation needed]

Applications

[

edit

]

Pressure reducing regulators

[

edit

]

Air compressors

[

edit

]

Air compressors are used in industrial, commercial, and home workshop environments to perform an assortment of jobs including blowing things clean; running air powered tools; and inflating things like tires, balls, etc. Regulators are often used to adjust the pressure coming out of an air receiver (tank) to match what is needed for the task. Often, when one large compressor is used to supply compressed air for multiple uses (often referred to as "shop air" if built as a permanent installation of pipes throughout a building), additional regulators will be used to ensure that each separate tool or function receives the pressure it needs. This is important because some air tools, or uses for compressed air, require pressures that may cause damage to other tools or materials.[citation needed]

Aircraft

[

edit

]

Pressure regulators are found in aircraft cabin pressurization, canopy seal pressure control, potable water systems, and waveguide pressurization.[3]

Aerospace

[

edit

]

Aerospace pressure regulators have applications in propulsion pressurant control for reaction control systems (RCS) and Attitude Control Systems (ACS), where high vibration, large temperature extremes and corrosive fluids are present.[4]

Cooking

[

edit

]

Pressurized vessels can be used to cook food much more rapidly than at atmospheric pressure, as the higher pressure raises the boiling point of the contents. All modern pressure cookers will have a pressure regulator valve and a pressure relief valve as a safety mechanism to prevent explosion in the event that the pressure regulator valve fails to adequately release pressure. Some older models lack a safety release valve[citation needed]. Most home cooking models are built to maintain a low and high pressure setting. These settings are usually 7 to 15 pounds per square inch (0.48 to 1.03 bar). Almost all home cooking units will employ a very simple single-stage pressure regulator. Older models will simply use a small weight on top of an opening that will be lifted by excessive pressure to allow excess steam to escape. Newer models usually incorporate a spring-loaded valve that lifts and allows pressure to escape as pressure in the vessel rises. Some pressure cookers will have a quick release setting on the pressure regulator valve that will, essentially, lower the spring tension to allow the pressure to escape at a quick, but still safe rate. Commercial kitchens also use pressure cookers, in some cases using oil based pressure cookers to quickly deep fry fast food. Pressure vessels of this sort can also be used as autoclaves to sterilize small batches of equipment and in home canning operations.[citation needed]

Water pressure reduction

[

edit

]

Pressure regulator for domestic water supply. Outlet pressure is set with the blue handwheel and shown on the vertical scale.

A water pressure regulating valve limits inflow by dynamically changing the valve opening so that when less pressure is on the outside, the valve opens up fully, and too much pressure on the outside causes the valve to shut. In a no pressure situation, where water could flow backwards, it won't be impeded. A water pressure regulating valve does not function as a check valve.[citation needed][clarification needed]

They are used in applications where the water pressure is too high at the end of the line to avoid damage to appliances or pipes.

Welding and cutting

[

edit

]

Oxy-fuel welding and cutting processes require gases at specific pressures, and regulators will generally be used to reduce the high pressures of storage cylinders to those usable for cutting and welding. Oxygen and fuel gas regulators usually have two stages: The first stage of the regulator releases the gas at a constant pressure from the cylinder despite the pressure in the cylinder becoming less as the gas is released. The second stage of the regulator controls the pressure reduction from the intermediate pressure to low pressure. The final flow rate may be adjusted at the torch. The regulator assembly usually has two pressure gauges, one indicating cylinder pressure, the other indicating delivery pressure. Inert gas shielded arc welding also uses gas stored at high pressure provided through a regulator. There may be a flow gauge calibrated to the specific gas.[citation needed]

Propane/LP gas

[

edit

]

All propane and LP gas applications require the use of a regulator. Because pressures in propane tanks can fluctuate significantly with temperature, regulators must be present to deliver a steady pressure to downstream appliances. These regulators normally compensate for tank pressures between 30'200 pounds per square inch (2.1'13.8 bar) and commonly deliver 11 inches water column 0.4 pounds per square inch (28 mbar) for residential applications and 35 inches of water column 1.3 pounds per square inch (90 mbar) for industrial applications. Propane regulators differ in size and shape, delivery pressure and adjustability, but are uniform in their purpose to deliver a constant outlet pressure for downstream requirements. Common international settings for domestic LP gas regulators are 28 mbar for butane and 37 mbar for propane.

If you are looking for more details, kindly visit Low Pressure Regulator.

Gas powered vehicles

[

edit

]

All vehicular motors that run on compressed gas as a fuel (internal combustion engine or fuel cell electric power train) require a pressure regulator to reduce the stored gas (CNG or Hydrogen) pressure from 700, 500, 350 or 200 bar (or 70, 50, 35 and 20 MPa) to operating pressure.[citation needed])

Recreational vehicles

[

edit

]

For recreational vehicles with plumbing, a pressure regulator is required to reduce the pressure of an external water supply connected to the vehicle plumbing, as the supply may be a much higher elevation than the campground, and water pressure depends on the height of the water column. Without a pressure regulator, the intense pressure encountered at some campgrounds in mountainous areas may be enough to burst the camper's water pipes or unseat the plumbing joints, causing flooding. Pressure regulators for this purpose are typically sold as small screw-on accessories that fit inline with the hoses used to connect an RV to the water supply, which are almost always screw-thread-compatible with the common garden hose.[citation needed]

Breathing gas supply

[

edit

]

Two-gauge pressure regulator connected to gas cylinder used for breathing gas supply

Pressure regulators are used with diving cylinders for Scuba diving. The tank may contain pressures in excess of 3,000 pounds per square inch (210 bar), which could cause a fatal barotrauma injury to a person breathing it directly. A demand controlled regulator provides a flow of breathing gas at the ambient pressure (which varies by depth in the water). Pressure reducing regulators are also use to supply breathing gas to surface-supplied divers,[5] and people who use self-contained breathing apparatus (SCBA) for rescue and hazmat work on land. The interstage pressure for SCBA at normal atmospheric pressure can generally be left constant at a factory setting, but for surface supplied divers it is controlled by the gas panel operator, depending on the diver depth and flow rate requirements. Supplementary oxygen for high altitude flight in unpressurised aircraft and medical gases are also commonly dispensed through pressure reducing regulators from high-pressure storage.[6][7]

Supplementary oxygen may also be dispensed through a regulator which both reduces the pressure, and supplies the gas at a metered flow rate, to be mixed with ambient air.[8] One way of producing a constant mass flow at variable ambient pressure is to use a choked flow, where the flow through the metering orifice is sonic. For a given gas in choked flow, the mass flow rate may be controlled by setting the orifice size or the upstream pressure. To produce a choked flow in oxygen, the absolute pressure ratio of upstream and downstream gas must exceed 1.893 at 20 °C. At normal atmospheric pressure this requires an upstream pressure of more than 1.013 × 1.893 = 1.918 bar. A typical nominal regulated gauge pressure from a medical oxygen regulator is 3.4 bars (50 psi), for an absolute pressure of approximately 4.4 bar and a pressure ratio of about 4.4 without back pressure, so they will have choked flow in the metering orifices for a downstream (outlet) pressure of up to about 2.3 bar absolute. This type of regulator commonly uses a rotor plate with calibrated orifices and detents to hold it in place when the orifice corresponding to the desired flow rate is selected. This type of regulator may also have one or two uncalibrated takeoff connections from the intermediate pressure chamber with diameter index safety system (DISS) or similar connectors to supply gas to other equipment, and the high pressure connection is commonly a pin index safety system (PISS) yoke clamp.[9] Similar mechanisms can be used for flow rate control for aviation and mountaineering regulators.

Mining industry

[

edit

]

As the pressure in water pipes builds rapidly with depth, underground mining operations require a fairly complex water system with pressure reducing valves. These devices must be installed at a certain vertical interval, usually 600 feet (180 m).[citation needed] Without such valves, pipes could burst and pressure would be too great for equipment operation.

Natural gas industry

[

edit

]

Pressure regulators are used extensively within the natural gas industry. Natural gas is compressed to high pressures in order to be distributed throughout the country through large transmission pipelines. The transmission pressure can be over 1,000 pounds per square inch (69 bar) and must be reduced through various stages to a usable pressure for industrial, commercial, and residential applications. There are three main pressure reduction locations in this distribution system. The first reduction is located at the city gate, whereas the transmission pressure is dropped to a distribution pressure to feed throughout the city. This is also the location where the odorless natural gas is odorized with mercaptan. The distribution pressure is further reduced at a district regulator station, located at various points in the city, to below 60 psig. The final cut would occur at the end users location. Generally, the end user reduction is taken to low pressures ranging from 0.25 psig to 5 psig. Some industrial applications can require a higher pressure.[citation needed]

Back-pressure regulators

[

edit

]

  • Maintain upstream pressure control in analytical or process systems[1]
  • Protect sensitive equipment from overpressure damage[1]
  • Reduce the pressure difference over a component which is not tolerant of large pressure differences.[10]
  • Gas sales lines[11]
  • Production vessels (e.g., Separators, heater treaters or free water knockouts)[11]
  • Vent or flare lines[11]

Hyperbaric chambers

[

edit

]

Where the pressure drop on a built-in breathing system exhaust system is too great, typically in saturation systems, a back-pressure regulator may be used to reduce the exhaust pressure drop to a safer and more manageable pressure.[10][12]

Reclaim diving helmets

[

edit

]

The depth at which most heliox breathing mixtures are used in surface-supplied diving is generally at least 5 bar above surface atmospheric pressure, and the exhaust gas from the diver must pass through a reclaim valve, which is a back-pressure valve activated by the increase in pressure in the diver's helmet above ambient pressure caused by diver exhalation.[13][14] The reclaim gas hose which carries the exhaled gas back to the surface for recycling must not be at too great a pressure difference from the ambient pressure at the diver. An additional back-pressure regulator in this line allows finer setting of the reclaim valve for lower work of breathing at variable depths.[15]

See also

[

edit

]

  • Built-in breathing system ' System for supply of breathing gas on demand within a confined space
  • Control valve ' Flow control device
  • Negative feedback ' Reuse of output to stabilize a system

References

[

edit

]

How Do Gas Pressure Regulators Work for Industrial ...

Any industrial process that requires industrial gases in its operations depends on gas distribution systems to deliver the gases from source to point-of-use safely and reliably. Among the cylinder, hoses, gauges, and other components that comprise a gas distribution system, gas pressure regulators play one of the most critical roles'controlling gas pressure. For anyone new to the operations or maintenance of a gas distribution system, it's well worth understanding how gas pressure regulators work.

How Do Gas Pressure Regulators Work?

In the simplest explanation, a gas pressure regulator reduces the inlet pressure to a lower outlet pressure and maintains a set outlet pressure, minimizing fluctuations in the inlet pressure. 

There are three elements in the regulator that control this process: 

  • Control element: also known as a poppet; is a spring-loaded valve
  • Sensing element: a piston or diaphragm
  • Load element:

    a spring

The interaction between these elements establishes and maintains the pressure in the following way: 

  • The force created by the spring opens the valve to allow gas from the inlet to flow through the pressure regulator.
  • Eventually, the gas pressure between the outlet and the point-of-use builds to a level and applies pressure to the sensing element which then begins to close the valve until a point where the valve remains sufficiently open to maintain the set pressure.

For a more detailed understanding of the science of gases, pressure, volume, temperature, and flow in 'Pressure Regulators Explained - Opening the Box of Mystery'.

Let's explore each of these elements to help gain a better understanding of how materials and design influence the performance of the gas pressure regulator.

A Closer Look at the Elements in a Gas Pressure Regulator

Most regulators use a spring-loaded 'poppet' (a rising and falling valve consisting of a disk at the end of a vertically set stem) for the control. The poppet includes an elastomeric seal to ensure a tight seal with the valve seat when the poppet is closed. A thermoplastic seal is used in some high-pressure gas regulator designs. The seal must be chemically compatible with the gas that flows through the regulator. 

The sensing element can be a diaphragm or a piston. A diaphragm is a thin disc-shaped elastomer (also compatible with the gas) that is used to sense changes in outlet pressure. In many regulators, the disc is made of thin metal. Diaphragms are preferred in low-pressure applications. Compared to a piston, a diaphragm can be more readily sized to provide a larger sensing area and thus provide higher accuracy in maintaining the correct gas pressure.

In comparison to a diaphragm, a piston design is more rugged and appropriate for higher outlet pressures. A piston does not respond as quickly to pressure changes because of the friction between the piston seal and the regulator body. As a result, the piston design is more appropriate for applications where lower accuracy in outlet pressure is acceptable. 

The loading element determines the pressure set-point. It is usually a mechanical spring that exerts a force on the sensing element (piston or diaphragm) which in turn opens the poppet. Most regulators adjust the pressure set-point by adjusting the force exerted by the mechanical spring. An adjustment screw or knob turned clockwise tightens the spring and increases set pressure. Turning it counterclockwise decreases set pressure. Alternatively, many regulators use a pressure signal captured within a dome above the sensing element in order to provide an accurate loading element that may be controlled by a pilot signal elsewhere. This is often utilized to ensure worker safety in hazardous environments, or to remotely control process pressure from an instrumentation control room. 

The Flow Curve Describes the Regulator's Operating Range

Every gas pressure regulator has a flow curve that describes its operating range. The flow curve is important in determining the useful regulating capacity. The flow curve has three sections:

  1. Seat-Load Drop or Lockup indicates the pressure above the set-point required to completely shut the regulator valve and prevent gas flow. When too much pressure builds up the gas regulator closes the poppet. 
  2. Ideal Operating Range is the area below the flow curve where the regulator provides the greatest control.
  3. Choked Flow

    is a limiting condition where any reduction in downstream pressure will have no effect on the flow rate for a fixed upstream pressure and temperature. In this state, the regulator valve is fully open and is no longer regulating pressure.

Pressure regulator accuracy is determined by plotting outlet pressure against flow rate. As the flow rate increases the outlet pressure drops. This relationship is termed 'droop.' The less droop a pressure regulator exhibits over a range of gas flow, the greater its accuracy in maintaining a set pressure. 

The last factor to consider is the Supply Pressure Effect. As the inlet pressure drops, say as a cylinder is nearing empty, the outlet pressure will increase. Sizing the regulator correctly for the application and using two-stage regulation are two important factors in sizing appropriately.

Single- and Dual-Stage Gas Pressure Regulators

Most gas distribution system designs feature single- or dual-stage regulators. Single-stage regulators have limited ranges of inlet pressure and/or flow rates. They are appropriate for small pressure reductions, for example, reducing plant compressed air service from 150 psi to 70 psi to operate air tools in the shop. 

Dual-stage regulators easily handle wide ranges of inlet pressures and flows, as well as the decreasing inlet pressure typical of gas cylinders. Dual-stage regulators are actually two regulators contained in a single regulator body. They include the components of a single-stage regulator with an additional stage that includes a second pressure adjusting spring, diaphragm, and poppet assembly. The advantage of dual-stage regulators is a near-complete elimination of the Supply Pressure Effect. The first stage pressure is set by the manufacturer. The second stage is adjustable by the user. 

Factors That Influence Gas Pressure Regulator Success

Selecting the right gas pressure regulator requires a good understanding of several factors specific to the industrial process and the type of regulator. A knowledgeable, experienced fluid systems engineer will carefully consider the following factors when recommending the right gas pressure regulator to work with an industrial process:

  • point-of-use application
  • operating temperature range
  • industrial gas to be used
  • toxic or flammable gas
  • inlet and outlet pressure ranges
  • range of inlet pressure fluctuations
  • allowable variation in outlet pressure
  • required flow rate
  • regulator material compatibility with the gas

These factors will help guide the selection of the type of gas pressure regulator that works best for the process. And, the review of the regulator flow curves for each of the possible regulators will guide the selection of the specific gas pressure regulator for the process.

Swagelok: Gas Regulator and Industrial Process Expertise

For more than 50 years, Swagelok has been assisting industries that rely on safe and reliable delivery of fluids and gases for their daily operations and manufacturing process. Swagelok is your local source for technical guidance, regulators to meet almost every gas distribution need, and design and assembly services to provide you with gas distribution systems tailored to your specific requirements. The components and gas distribution systems sold and assembled by Swagelok are backed by our Limited Lifetime Warranty.

To find out more about how Swagelok Northern California can assist you in the selection of gas pressure regulators and the design of gas distribution systems by providing expert consultation and assembly services, contact our team today by calling 510-933-.

Morgan Zealear | Product Engineer ' Assembly Services

Morgan holds a B.S. in Mechanical Engineering from the University of California at Santa Barbara. He is certified in Section IX, Grab Sample Panel Configuration, and Mechanical Efficiency Program Specification (API 682). He is also well-versed in B31.3 Process Piping Code. Before joining Swagelok Northern California, he was a Manufacturing Engineer at Sierra Instruments, primarily focused on capillary thermal meters for the semiconductor industry (ASML).

If you want to learn more, please visit our website Lpg Fittings.