Shipment
The company is the world’s best Gb/T 31484-2015 supplier. We are your one-stop shop for all needs. Our staff are highly-specialized and will help you find the product you need.
The cell shall be shipped in voltage range of 3.5~ 3.8V or in accordance with customers' requirement. The remaining capacity before charging shall be changed depending on the storage time and conditions
100pcs cells in a small box, 2 small boxes in a big box
Storage
Conditions Permissible time -20℃~ 60℃, 60% RH Max Less than 1 month -20℃~45℃, 60% RH Max Less than 3 months -20℃~25℃, 60% RH Max Less than 1 year About long time storage:If the cellneeds to bestored for a long time, the cell’s storage voltage should be 3.5~ 3.8V. Also, it is recommended to charge the cellevery six months.Warranty
The Warranty period of cell is made according to business contract. However, even though the problem occurs within this period, BAK won’t replace a new cell for free as long as the problem is not due to the failure of manufacturing process or is due to customers’ abuse or misuse.
Regenerative Battery Pack Test System
Battery Charge Discharge Test Equipment
Product description:
The battery charge discharge test equipment is a professional and reliable regenerative battery pack test system, by charging and discharging battery packs such as EV batteries, HEV batteries, ESS batteries, and telecommunications system batteries, and collecting test data in real time, the battery charge discharge test equipment obtains battery electrical performance test data, which provides an accurate and reliable basis for battery quality control, R&D and application simulation.
The regenerative battery pack test system is equipped with a bidirectional AC/DC converter, which can regenerate battery discharge energy to the AC power grid, saving power and testing costs.
Scope of application:
The battery charge discharge test equipment can be used to test the electrical performance of various types of batteries such as lithium batteries, Ni-Cd batteries, NiMH batteries, lead-acid batteries, and flow batteries, etc.
In addition, the regenerative battery pack test system can also be used to perform aging tests on various electronic loads, such as charger aging tests.
Main test items:
1. Battery pack capacity test.
2. Battery pack charge/discharge performance test.
3. Battery pack charge/discharge efficiency test.
4. Battery pack charge retention and recovery ability test.
5. Battery pack cycle life test.
6. Battery pack temperature characteristics test.
7. Battery pack DC internal resistance test.
8. Battery pack pulse charge/discharge test.
9. Battery pack working condition simulation test.
10. Battery pack over-charge and over-discharge rate affordability test.
System Topology:
Figure 1. System Topology of Regenerative Battery Pack Test System
Features:
1. Regenerative design, using a common DC bus topology, energy conversion between DC channels can be achieved. And, battery discharge energy is preferentially regenerated between DC channels.
2. Regenerative design, if the DC channels cannot be balanced, the extra battery discharge energy will be regenerated to the AC power grid, which saves power and test costs.
3. The power control scheme of DSP&IGBT is adopted to achieve high-speed and high-precision control of electric energy.
4. The margin and timely power control algorithm ensures the stable and reliable operation of regenerative battery pack test system.
5. The output voltage range, current range, and power range can be freely set, and it is compatible with battery packs of various specifications and models.
6. AC input adopts adaptive technology and does not need to distinguish the phase sequence of the AC power grid.
7. Advanced software phase locking control technology, THD≤5%.
8. Scan the QR code to automatically bind the test process file, and scan the QR code to automatically start testing, avoiding manual errors and improving testing efficiency.
9. Supports automatic judgment of unqualified batteries to improve testing efficiency.
Technical Specifications of Regenerative Battery Pack Test System
Product name
Battery Charge Discharge Test Equipment
Product model
WA-BTS-RJ550V500A2CH550kW
Product type
Regenerative type
Regeneration efficiency
≤94% (Full load)
Energy regeneration features
a) Battery discharge energy is preferentially regenerated between DC channels.
b) If the DC channels cannot be balanced, the extra battery discharge energy will be regenerated to the AC power grid.
AC Input Side
AC input power
Voltage: 380VAC±15%
Frequency: 50Hz±2Hz
(Customizable)
a) Three-phase five-wire power distribution system;
b) Grounding resistance ≤5Ω.
Power factor
≥99%
Full load
The Harmonic Distortion
THD≤5%
Full load
AC input protections
AC power grid under-voltage protection
AC power grid over-voltage protection
AC power grid over-current protection
Includes circuit breaker over-current protection.
AC power grid over-load protection
AC power grid input phase loss protection
AC power grid frequency exception protection
Transformer over-temperature protection
Lightning protection
Anti-islanding effect protection
DC Output Side
Output channel
No. of channels
2 channels/cabinet
Customizable
Channels used in parallel
Yes
Up to 1000A after paralleling of circuits.
Channel control mode
Independent control of each channel
Detection and Sampling
Four-wire measurement
Voltage/CH
Charge range
DC: 0V~550V
Customizable
Discharge range
DC: 550V~30V
Customizable
Accuracy
±(0.05%FS+0.05%RD)
Customizable
Resolution
0. 1mV
Current/CH
Range
DC: ±500A
Customizable
Accuracy
±(0.05%FS+0.05%RD)
Customizable
Resolution
0. 1mA
Maximum power/CH
275kW
Maximum power/Cabinet
550kW
Current rise time
≤30ms
10%~90% (Battery load)
Current switch time
≤60ms
-90%~+90% (Battery load)
Data collection interval
≤10ms
Includes current and voltage values.
DC output protections
Under-voltage protection
Over-voltage protection
Short-circuit protection
Over-temperature protection
Reverse connection protection
Over-current protection
Channel communication exception protection
Automatically disconnect output if communication exception occurs.
Power outage protection
Automatically disconnect contactor during power outage
Emergency stop protection
Includes emergency stop button.
Other Parameters
Heat dissipation
Air forced cooling
IP Rating
IP20
Sound
≤75dB
Measured from 1 meter away.
Lightning protection level
Level 2
AC cable lead-in method
Bottom lead-in
DC cable lead-out method
Bottom lead-out
Customizable
Output cable
5 m copper cable with tinned copper nose terminals
Customizable
BMS communication interface
Each channel contains one CAN communication
Each channel is configured with one 12V power supply.
Cabinet color
WinAck standard cabinet colors
Customizable
If you want to learn more, please visit our website lithium ion batteries storage.
Reference dimensions
W1840*D1100*H1900mm
Subject to actual situation.
Usage Environment Requirements
Altitude
≤1000m
Working temperature
- 10℃~45℃
Relative humidity
≤90%RH
Non-condensing
Storage temperature
-20℃~50℃
Installation environment
a) No strong vibration and impact;
b) No strong electromagnetic interference.
a) The intensity of external magnetic field induction shall not exceed 0.5m;
b) The vertical slope of the installation should not exceed 5%.
Usage environment
a) No explosive hazardous media;
b) Does not contain harmful substances that corrode metal and damage insulation;
c) Does not contain conductive media;
d) Mold is not allowed.
Software Functions of Regenerative Battery Pack Test System
Items
Function description
Remarks
Database type
MYSQL
Data storage interval
0.1S~9999S
Configurable
Nested Loop function
Max. support 5 layers
Hierarchical display of process flow.
Editable number of steps
Max. 9999
Number of cycles
1~9999
DBC file parsing function
Supports importing and editing of standard format DBC files
Working condition simulation function
Supports import of EXCEL working condition files
Contains current working condition files and power working condition files; time and moment are optional.
Charge mode
Constant current charge
If you have any other charge mode requirements, please consult us.
Constant voltage charge
Constant current to constant voltage charge
Constant power charge
Constant resistance charge
Power follower
Current follower
Discharge mode
Constant current discharge
If you have any other discharge mode requirements, please consult us.
Constant voltage discharge
Constant power discharge
Constant resistance discharge
Power follower
Current follower
Cut-off condition
(Jump condition or if condition)
Working step time
a) BMS data conditions require BMS to upload relevant data to be valid.
b) If you have any other cut-off condition requirements, please consult us.
Voltage
Current
Capacity (Total capacity, charging capacity, discharging capacity)
Maximum cell voltage
Minimum cell voltage
Maximum cell temperature
Cell voltage difference
Cell temperature difference
SOC
Global control conditions
Output voltage range
BMS data conditions require BMS to upload relevant data to be valid.
Current range
Power range
Cell voltage range
Cell temperature range
Cell voltage difference range
Cell temperature difference range
Unqualified battery judgment conditions
Working step capacity
It is optional to continue to the next work step or stop testing after being judged as unqualified.
Total capacity
End current
Battery voltage
Working Step energy
Battery voltage difference
Battery temperature difference
SOC
Software protections
Output limit protection
The output voltage, current and power range can be set.
BMS data anomaly protection
Including cell voltage, cell temperature, cell voltage difference, cell temperature difference, etc.
Communication abnormality protection
a) PC communication abnormality protection;
b) BMS data abnormality protection.
Abnormal power outage protection
Support work step continuation function.
Voltage over range protection
When the voltage is out of range, the work step cannot be performed.
Reverse connection protection
When the connection is reversed, the work step cannot be performed.
Data output
Support single channel data export.
Export data in batches.
Export content is optional.
Supports curve graph export.
Supports exporting after data filtering.
Data list content
Detailed data list
Cycle list
Work step statistics list
Log file
Test process
Test report
Curve graphics
Permission management
Supports three-level permission management functions of super administrator, test administrator, and test operator.
MES uploading function
Upload data to MES as required.
Optional
Scan code function
Scan the barcode or QR code to automatically start the test.
We can set whether to enable this function.
Supports automatic binding test process by scanning barcode or QR code.
Automatically bind the test process to the battery pack coding rules and automatically start the test.
LAN function
Supports automatic synchronization of test process files between multiple PCs in the LAN.
A separate server is required.
Supports searching test data between multiple PCs in the LAN.
Test data between different PCs can be quickly searched, and scan code search is supported.
Test result judgment
Supports automatic judgment of unqualified batteries.
Unqualified conditions can be set freely and test results are automatically generated.
DCIR test
Support
Test parameters can be set.
Support database migration
Support
Reference Standards:
1) GB/T 18386.1-2021 Test methods for energy consumption and range of electric vehicles—Part 1: Light-duty vehicles
2) GB/T 18386.2-2022 Test methods for energy consumption and range of electric vehicles—Part 2: Heavy-duty commercial vehicles
3) GB/T 31484-2015 Cycle life requirements and test methods for traction battery of electric vehicle
4) GB/T 31486-2015 Electrical performance requirements and test methods for traction battery of electric vehicle
5) GB 38031-2020 Electric vehicles traction battery safety requirements
6) GB/T 18385-2005 Electric vehicles Power performance Test method
7) GB/T 31467.1-2015 Lithium-ion traction battery pack and system for Electric vehicles—Part 1: Test specification for High power applications
8) GB/T 31467.2-2015 Lithium-ion traction battery pack and system for Electric vehicles—Part 2: Test specification for High energy applications
Figure 2. Regenerative Battery Pack Test System
* Reference picture (Picture just as reference, please in kind prevail)
For more lithium iron phosphate battery energy storage systeminformation, please contact us. We will provide professional answers.